Designer

Termex Cellulose insulation is a safe, researched product for ecological building

A successful design solution requires correct product information. You can find all the relevant research and certification information for Termex Cellulose insulation on this page. If necessary, you can request site-specific advice through our technical support.

Termex Cellulose insulation in a nutshell

1. Thermal conductivity λD (23,50) 038 W/mK

2. AFr airflow resistance 4–40 kPa S/m2 (26–60 kg/m3)

3. Euroclass, reaction to fire  B-s2,d0 (Very Limited contribution to fire)

4. Mould index 0

5. Water vapour permeability µ = 1.4

6. Settlement:

  • 10% (dry open blow: attics, intermediate floors)
  • 0% (dense blow: wall and closed roof cavities, floors)
  • 0% (Sidox-application: attics and wall cavities)

7. Specific heat capacity 1600 kJ/kg

8. GWP 105 g CO2e/kg

9. Biogenic carbon storage 1350 g CO2e/kg

Termex air barrier products in a nutshell

Kraft air barrier  paper

  1. Square weight 180 g/m2
  2. Roll width 1250 mm
  3. Square metres in a roll 60 m2
  4. Thickness 0.2 mm
  5. Tensile strength in longitudinal direction 872 kN/m
  6. Tensile strength in transversal direction 430 kN/m
  7. Water vapour permeability µ = 0.61

Retro air barrier paper

  1. Square weight 200 g/m2
  2. Roll width 1325 mm
  3. Square metres in a roll 60 m2
  4. Thickness 0.275 mm
  5. Tensile strength in longitudinal direction 1820 kN/m
  6. Tensile strength in transversal direction 695 kN/m
  7. Water vapour permeability µ = 0.07

Manufacturer: Eltete Oy

Certificates and product information:

Instructions and product descriptions

Documentation

Litterature and research data

Case study

u

FAQ

Videos

Material Calculator

Data Bank